User Tools

Site Tools


himd_device_control

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
himd_device_control [2010/05/21 17:36] megadiscmanhimd_device_control [2010/06/27 10:20] (current) – Fix time bit numbers megadiscman
Line 17: Line 17:
   * Application ID: 0   * Application ID: 0
   * Used fields: flags.   * Used fields: flags.
-    * Bit 0: IMMED ("immediate": finish SCSI handling before command finishes - MUST be set, command is rejected otherwise by the RH-1)+    * Bit 0: IMMED ("immediate": finish SCSI handling before command finishes - must be set on RH-1)
     * Bit 1: FUA ("force unit access": write now, don't cache)     * Bit 1: FUA ("force unit access": write now, don't cache)
-**Note:** Seems to work only with Standard MD media.+ 
 +This command completely blanks the medium. This is not possible with Hi-MD 1GB media, as the Disc ID is read-only. Standard MD media completely blanked are usable in standard MD devices. This is the only way getting rid of Hi-MD format on a standard MD medium.
  
 === Subcommand 01: Format HiMD === === Subcommand 01: Format HiMD ===
   * Application ID: 0   * Application ID: 0
   * Used fields: flags.   * Used fields: flags.
-    * Bit 0: IMMED ("immediate": finish SCSI handling before command finishes)+    * Bit 0: IMMED ("immediate": finish SCSI handling before command finishes - must be set on RH-1)
     * Bit 1: FUA ("force unit access": write now, don't cache)     * Bit 1: FUA ("force unit access": write now, don't cache)
-    * Bit 2: NOFS (Don't generate FAT FS?) +    * Bit 2: NOFS (Don't generate FAT FS? - must be cleared on RH-1
-**Note:** Maybe works with Hi-MD 1GB mediatoo.+ 
 +This command just reinitializes the Hi-MD data structures on the Medium, but it doesn't remove the Hi-MD layout from it. It generally keeps the Disc ID, as this data is stored *outside* of the area accessible using normal read/write instructionsand only this area is reinitialized.
  
 === Subcommand 0E: Begin ICV Transaction === === Subcommand 0E: Begin ICV Transaction ===
Line 68: Line 70:
 Reads a 7-byte data packet from the Hi-MD unit with the following layout: Reads a 7-byte data packet from the Hi-MD unit with the following layout:
  
-  Byte 00: Flags. Bit = Ex; Bit = Ef; Bit = WP (write protect?)+  Byte 00: Flags. Bit = Ex; Bit = Ef; Bit = WP (write protect?)
   Byte 01: second   Byte 01: second
   Byte 02: minute   Byte 02: minute
himd_device_control.1274463372.txt.gz · Last modified: 2010/05/21 17:36 by megadiscman